- Measuring System: Amperometric Potentiostatic 2-Electrode System
- Measuring Range: 0.005 – 2.000 ppm ; 0.05 – 20.00 ppm ; 0 – 2000 ppm
- Electronic: Digital Modbus RTU
- Operating Temperature: 0 – 45°C
- Temperature Compensation: Automatically by an integrated temperature sensor
- Operating Pressure: 0.5 bar in the flow cell
- Flow Rate: Approx. 15 – 30 L/h in flow cell
- pH Range: pH 4 – 12, highly reduced dependence on pH value ; pH 5 – 8
- Run-in Time: First start-up approx. 2 hours ; First start-up approx. 11 hours
- Response Time: T90 approx. 8 minutes
- Slope Calibration: DPD-1 Method (up to 10 ppm)
- Interferences: Chlorine Dioxide (ClO2), Ozone (O3), Peracetic Acid
- Power Supply: 9 – 30 VDC
- Dimension: Diameter: 25mm ; Length: 205mm
- Material: Semipermeable Membrane, PVC-U, PEEK, Stainless Steel 1.4571
Digital Free Chlorine – FC1N
Leadtec Digital Free Chlorine sensor consists of either two or three electrode sensor in which the measuring electrode is Benefits made of gold and the reference electrode is made of silver with a silver halide coating. For 3-electrode sensor, it has additional counter electrode is made of stainless steel. The sensor can measure the real-time reading without the reagent.
Category Free Chlorine Sensor
Tag Sensor
Be the first to review “Digital Free Chlorine – FC1N” Cancel reply






Reviews
There are no reviews yet.